{"items":[{"id":26,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"CISA Adds Four Known Exploited Vulnerabilities to Catalog","summary":"CISA has added four new vulnerabilities to its\nKnown Exploited Vulnerabilities (KEV) Catalog\n, based on evidence of active exploitation.\n\nCVE-2025-42884\nSAP NetWeaver Improper Neutralization of Special Elements in Data Query Logic Vulnerability\n\nCVE-2026-76466\nCisco Expressway Series Use of Hard-coded Credentials Vulnerability\n\nCVE-2026-123890\nVMWare vCenter Authentication Bypass Using an Alternate Path or Channel Vulnerability\n\nCVE-2026-129448\nApache Roller Deserialization of Untrusted Data Vulnerability\n\nThese types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.\n\nBinding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk\nestablishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.\n\nWhile BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of\nKEV Catalog vulnerabilities\n. CISA will continue to add vulnerabilities to the catalog that meet the\nspecified criteria\n.\n\nAware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s\nKEV Nomination Form\n. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.","url":"https://cisa.gov/news-events/alerts/2026/11/20/cisa-adds-four-known-exploited-vulnerabilities-catalog","published_at":"2026-11-20T12:00:00Z","updated_at":"2026-11-20T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028648Z","severity":"critical","cvss_score":9.8,"epss":0.05459,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-23","vendor":"cisco","product":"NetWeaver","vuln_id":"CVE-2025-42884","vuln_ids":["CVE-2025-42884","CVE-2026-123890","CVE-2026-129448","CVE-2026-76466","CVE-2026-82384"],"tags":[],"cluster_id":7,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/26","html":"https://vulnwatch.ve1ve2.com/item/26"}},{"id":29,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Autonomy Logic OpenPLC Runtime","summary":"View CSAF\n\nSummary\n\nSuccessful exploitation of this vulnerability could allow several unauthenticated admin accounts to be created.\n\nThe following versions of Autonomy Logic OpenPLC Runtime are affected:\n\nOpenPLC Runtime <=4.2.4 (CVE-2026-126088)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 8.1\n\nAutonomy Logic\n\nOpenPLC Runtime\n\n1 Vulnerability\n\nConcurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing, Energy, Transportation Systems, Water and Wastewater Systems\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nUnited States\n\nVulnerabilities\n\nCVE-2026-126088\n\nIn Autonomy Logic OpenPLC Runtime versions 4.2.4 and prior, a race condition allows multiple concurrent requests to pass the existence check before any user is committed, resulting in several unauthenticated admin accounts being created.\n\nRead More\n\n1 Affected Product\n\nAutonomy Logic OpenPLC Runtime <=4.2.4\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to OpenPLC Runtime version 4.3.0 or later.\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-362 Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n8.1\n\nHIGH\n\nCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\n\n4.0\n\n9.2\n\nCRITICAL\n\nCVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\n\nView CVE Details\n\nAcknowledgments\n\nNoureddin Lutfi reported this vulnerability to CISA.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for\ncontrol systems security recommended practices\non the ICS webpage on\ncisa.gov/ics\n. Several CISA products detailing cyber defense best practices are available for reading and download, including\nImproving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies\n.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for\nproactive defense of ICS assets\n.\n\nAdditional mitigation guidance and recommended practices are publicly available on the ICS webpage at\ncisa.gov/ics\nin the technical information paper,\nICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies\n.\n\nOrganizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.\n\nCISA also recommends users take the following measures to protect themselves from social engineering attacks:\n\nDo not click web links or open attachments in unsolicited email messages.\n\nRefer to\nRecognizing and Avoiding Email Scams\nfor more information on avoiding email scams.\n\nRefer to\nAvoiding Social Engineering and Phishing Attacks\nfor more information on social engineering attacks.\n\nNo known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.\n\nRevision History\n\nInitial Release Date:\n2026-11-19\n\nDate\n\nRevision\n\nSummary\n\n2026-11-19\n\n1\n\nInitial Publication\n\nLegal Notice and Terms of Use","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-323-01","published_at":"2026-11-19T12:00:00Z","updated_at":"2026-11-19T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028668Z","severity":"critical","cvss_score":9.2,"epss":0.00268,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-126088","vuln_ids":["CVE-2026-126088"],"tags":[],"cluster_id":14,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/29","html":"https://vulnwatch.ve1ve2.com/item/29"}},{"id":28,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"libumqtt","summary":"View CSAF\n\nSummary\n\nSuccessful exploitation of this vulnerability could allow a remote attacker to cause a denial of service, memory corruption, or information disclosure.\n\nThe following versions of libumqtt are affected:\n\nlibumqtt <=1.1.1 (CVE-2026-125132)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 8.6\n\nlibumqtt\n\nlibumqtt\n\n1 Vulnerability\n\nInteger Underflow (Wrap or Wraparound)\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing, Energy, Information Technology, Transportation Systems, Water and Wastewater\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nChina\n\nVulnerabilities\n\nCVE-2026-125132\n\nThe affected product is vulnerable to an integer underflow which may allow a remote attacker to cause a denial of service, memory corruption, or information disclosure.\n\nRead More\n\n1 Affected Product\n\nlibumqtt libumqtt <=1.1.1\n\nProduct Status: known_affected\n\nRemediations\n\nNone available\nThe repository owners of libumqtt did not respond to CISA's request for coordination. Users are encouraged to reach out to libumqtt for support. Their GitHub page is located at https://github.com/zhaojh329/libumqtt.\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-191 Integer Underflow (Wrap or Wraparound)\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n8.6\n\nHIGH\n\nCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H\n\n4.0\n\n8.8\n\nHIGH\n\nCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N\n\nView CVE Details\n\nAcknowledgments\n\nJoseph Devasia reported this vulnerability to CISA\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for\ncontrol systems security recommended practices\non the ICS webpage on\ncisa.gov/ics\n. Several CISA products detailing cyber defense best practices are available for reading and download, including\nImproving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies\n.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for\nproactive defense of ICS assets\n.\n\nAdditional mitigation guidance and recommended practices are publicly available on the ICS webpage at\ncisa.gov/ics\nin the technical information paper,\nICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies\n.\n\nOrganizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.\n\nCISA also recommends users take the following measures to protect themselves from social engineering attacks:\n\nDo not click web links or open attachments in unsolicited email messages.\n\nRefer to\nRecognizing and Avoiding Email Scams\nfor more information on avoiding email scams.\n\nRefer to\nAvoiding Social Engineering and Phishing Attacks\nfor more information on social engineering attacks.\n\nNo known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.\n\nRevision History\n\nInitial Release Date:\n2026-11-19\n\nDate\n\nRevision\n\nSummary\n\n2026-11-19\n\n1\n\nInitial Publication\n\nLegal Notice and Terms of Use","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-323-03","published_at":"2026-11-19T12:00:00Z","updated_at":"2026-11-19T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028666Z","severity":"high","cvss_score":8.8,"epss":0.00838,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-125132","vuln_ids":["CVE-2026-125132"],"tags":[],"cluster_id":13,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/28","html":"https://vulnwatch.ve1ve2.com/item/28"}},{"id":27,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Elecbrakes EB2, VM1, ELBC2000","summary":"View CSAF\n\nSummary\n\nSuccessful exploitation of these vulnerabilities could allow an attacker to gain control of the brakes of a trailer, modify the firmware, disable the brake lights, modify the brake conditions or disable other critical safety features.\n\nThe following versions of Elecbrakes EB2, VM1, ELBC2000 are affected:\n\nEB2 <=3.0.4.2.0 (CVE-2026-124281, CVE-2026-125273, CVE-2026-96805)\n\nELBC2000 vers:all/* (CVE-2026-124281, CVE-2026-125273, CVE-2026-96805)\n\nVM1 <1.3.4.2.1 (CVE-2026-124281, CVE-2026-125273, CVE-2026-96805)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 9.6\n\nElecbrakes\n\nEB2\n\n3 Vulnerabilities\n\nExposed Dangerous Method or Function, Authentication Bypass by Capture-replay, Missing Authentication for Critical Function\n\nBackground\n\nCritical Infrastructure Sectors:\nTransportation Systems\n\nCountries/Areas Deployed:\nAustralia, New Zealand\n\nCompany Headquarters Location:\nAustralia\n\nVulnerabilities\n\nExpand All +\n\nCVE-2026-124281\n\nThe affected product uses an unprotected firmware-update channel, which may allow for unauthorized firmware modification.\n\nRead More\n\n3 Affected Products\n\nElecbrakes EB2 <=3.0.4.2.0\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nElecbrakes has released updated firmware (EB2 3.0.4.4.3). Users should open the Elecbrakes app and install the firmware update.\n\nElecbrakes VM1 <1.3.4.2.1\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nElecbrakes has released updated firmware (VM1 1.3.4.2.1). Users should open the Elecbrakes app and install the firmware update.\n\nElecbrakes ELBC2000 vers:all/*\n\nProduct Status: known_affected\n\nRemediations\n\nNone available\nThis device is the predecessor to the EB2 and the VM1 and is no longer sold. The vendor is determining how to address these vulnerabilities for this particular controller.\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-749 Exposed Dangerous Method or Function\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n6.1\n\nMEDIUM\n\nCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:L\n\n4.0\n\n5.3\n\nMEDIUM\n\nCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:L/SA:L\n\nView CVE Details\n\nCVE-2026-125273\n\nNo replay or command-integrity protection. Commands lack sequence numbers, nonces, or session tokens; captured commands can be replayed, and the last command persists across sessions.\n\nRead More\n\n6 Affected Products\n\nElecbrakes EB2 <=3.0.4.2.0\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nElecbrakes has released updated firmware (EB2 3.0.4.4.3). Users should open the Elecbrakes app and install the firmware update.\n\nElecbrakes VM1 <1.3.4.2.1\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nElecbrakes has released updated firmware (VM1 1.3.4.2.1). Users should open the Elecbrakes app and install the firmware update.\n\nElecbrakes ELBC2000 vers:all/*\n\nProduct Status: known_affected\n\nRemediations\n\nNone available\nThis device is the predecessor to the EB2 and the VM1 and is no longer sold. The vendor is determining how to address these vulnerabilities for this particular controller.\n\nElecbrakes EB2 <=3.0.4.2.0\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nElecbrakes has released updated firmware (EB2 3.0.4.4.3). Users should open the Elecbrakes app and install the firmware update.\n\nElecbrakes ELBC2000 vers:all/*\n\nProduct Status: known_affected\n\nRemediations\n\nNone available\nThis device is the predecessor to the EB2 and the VM1 and is no longer sold. The vendor is determining how to address these vulnerabilities for this particular controller.\n\nElecbrakes VM1 <1.3.4.2.1\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nElecbrakes has released updated firmware (VM1 1.3.4.2.1). Users should open the Elecbrakes app and install the firmware update.\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-294 Authentication Bypass by Capture-replay\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n9.6\n\nCRITICAL\n\nCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H\n\n4.0\n\n8.5\n\nHIGH\n\nCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/S:P\n\nV…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-323-02","published_at":"2026-11-19T12:00:00Z","updated_at":"2026-11-19T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028663Z","severity":"high","cvss_score":8.5,"epss":0.01459,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-124281","vuln_ids":["CVE-2026-124281","CVE-2026-125273","CVE-2026-96805"],"tags":[],"cluster_id":10,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/27","html":"https://vulnwatch.ve1ve2.com/item/27"}},{"id":30,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"CISA Adds Four Known Exploited Vulnerabilities to Catalog","summary":"CISA has added four new vulnerabilities to its\nKnown Exploited Vulnerabilities (KEV) Catalog\n, based on evidence of active exploitation.\n\nCVE-2024-10441\nSynology DiskStation Manager (DSM) Improper Encoding or Escaping of Output Vulnerability\n\nCVE-2026-40217\nBerriAI LiteLLM Unprotected Alternate Channel Vulnerability\n\nCVE-2026-90436\nApache Axis Unsafe Reflection Vulnerability\n\nCVE-2026-90817\nVanderbilt University Research Electronic Data Capture (REDCap) Code Injection Vulnerability\n\nThese types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.\n\nBinding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk\nestablishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.\n\nWhile BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of\nKEV Catalog vulnerabilities\n. CISA will continue to add vulnerabilities to the catalog that meet the\nspecified criteria\n.\n\nAware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s\nKEV Nomination Form\n. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.","url":"https://cisa.gov/news-events/alerts/2026/11/18/cisa-adds-four-known-exploited-vulnerabilities-catalog","published_at":"2026-11-18T12:00:00Z","updated_at":"2026-11-18T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028671Z","severity":"critical","cvss_score":9.8,"epss":0.78004,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-21","vendor":"apache","product":"DiskStation Manager (DSM)","vuln_id":"CVE-2024-10441","vuln_ids":["CVE-2024-10441","CVE-2026-40217","CVE-2026-90436","CVE-2026-90817"],"tags":[],"cluster_id":15,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/30","html":"https://vulnwatch.ve1ve2.com/item/30"}},{"id":43,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"CISA Adds One Known Exploited Vulnerability to Catalog","summary":"CISA has added one new vulnerability to its\nKnown Exploited Vulnerabilities (KEV) Catalog\n, based on evidence of active exploitation.\n\nCVE-2026-115731\nPerforce Puppet Enterprise Deserialization of Untrusted Data Vulnerability\n\nThis type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.\n\nBinding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk\nestablishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.\n\nWhile BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of\nKEV Catalog vulnerabilities\n. CISA will continue to add vulnerabilities to the catalog that meet the\nspecified criteria\n.\n\nAware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s\nKEV Nomination Form\n. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.","url":"https://cisa.gov/news-events/alerts/2026/11/17/cisa-adds-one-known-exploited-vulnerability-catalog","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028706Z","severity":"critical","cvss_score":9.4,"epss":0.01231,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-12-01","vendor":"Perforce","product":"Puppet Enterprise","vuln_id":"CVE-2026-115731","vuln_ids":["CVE-2026-115731"],"tags":[],"cluster_id":36,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/43","html":"https://vulnwatch.ve1ve2.com/item/43"}},{"id":42,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens meta-iot2050","summary":"View CSAF\n\nSummary\n\nmeta-iot2050 (https://github.com/siemens/meta-iot2050) from V01.03.01 contains a Command Injection vulnerability in the firmware update tool that could allow an attacker which is able to manipulate a configuration file to have arbitrary commands run as root. Siemens is preparing fixes and recommends mitigations for products where fixes are not or not yet available.\n\nThe following versions of Siemens meta-iot2050 are affected:\n\nmeta-iot2050 vers:intdot/>=01.03.01 (CVE-2026-109830)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 7.3\n\nSiemens\n\nmeta-iot2050\n\n1 Vulnerability\n\nImproper Neutralization of Special Elements used in an OS Command ('OS Command Injection')\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing, Energy, Information Technology\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-109830\n\nAffected devices take parts from a configuration file and execute them unchecked. This could allow an attacker which is able to manipulate the configuration file to make the user execute arbitrary code on the device.\n\nRead More\n\n1 Affected Product\n\nmeta-iot2050 >= V01.03.01\n\nProduct Status: known_affected\n\nRemediations\n\nNone available\nCurrently no fix is available\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n7.3\n\nHIGH\n\nCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported this vulnerability to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for\ncontrol systems security recommended practices\non the ICS webpage on\ncisa.gov/ics\n. Several CISA products detailing cyber defense best practices are available for reading and download, including\nImproving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies\n.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for\nproactive defense of ICS assets\n.\n\nAdditional mitigation guidance and recommended practices are publicly available on the ICS webpage at\ncisa.gov/ics\nin the technical information paper,\nICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies\n.\n\nOrganizations observing suspected malicious…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-11","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028703Z","severity":"low","cvss_score":3.1,"epss":0.00173,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-109830","vuln_ids":["CVE-2026-109830"],"tags":[],"cluster_id":35,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/42","html":"https://vulnwatch.ve1ve2.com/item/42"}},{"id":41,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens SIMATIC WinCC","summary":"View CSAF\n\nSummary\n\nGraphics Designer of SIMATIC WinCC before V8.2 contains an implicit active content execution vulnerability upon opening files, which could allow an attacker to cause arbitrary code execution on the device. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.\n\nThe following versions of Siemens SIMATIC WinCC are affected:\n\nSIMATIC WinCC V7.5 vers:all/* (CVE-2026-59082)\n\nSIMATIC WinCC V8.0 vers:all/* (CVE-2026-59082)\n\nSIMATIC WinCC V8.1 vers:all/* (CVE-2026-59082)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 7.8\n\nSiemens\n\nSIMATIC WinCC V7.5\n\n1 Vulnerability\n\nInsufficient UI Warning of Dangerous Operations\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-59082\n\nAffected devices implicitly execute active content when opening files. This could allow an attacker to make the user execute arbitrary code on the device.\n\nRead More\n\n3 Affected Products\n\nSIMATIC WinCC V7.5\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nThe affected product may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with the affected product. Also make sure to only open files from trusted sources.\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC V8.0\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nThe affected product may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with the affected product. Also make sure to only open files from trusted sources.\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC V8.1\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nThe affected product may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with the affected product. Also make sure to only open files from trusted sources.\n\nNone available\nCurrently no fix is available\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-357 Insufficient UI Warning of Dangerous Operations\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n7.8\n\nHIGH\n\nCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported this vulnerability to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\nRecommended Practices\n\nCISA recommends users take defensive…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-09","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028701Z","severity":"low","cvss_score":3.1,"epss":0.00126,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-59082","vuln_ids":["CVE-2026-59082"],"tags":[],"cluster_id":34,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/41","html":"https://vulnwatch.ve1ve2.com/item/41"}},{"id":40,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens RUGGEDCOM APE1808","summary":"View CSAF\n\nSummary\n\nFortinet has published information on a Double Free vulnerability in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to update Fortigate NGFW to V7.6.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information\n\nThe following versions of Siemens RUGGEDCOM APE1808 are affected:\n\nRUGGEDCOM APE1808 vers:all/* (CVE-2026-106175)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 2.3\n\nSiemens\n\nRUGGEDCOM APE1808\n\n1 Vulnerability\n\nDouble Free\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-106175\n\nA Double Free vulnerability [CWE-415] in FortiOS, FortiProxy and FortiSwitch may allow a local authenticated attacker to crash the newcli daemon via crafted CLI commands.\n\nRead More\n\n1 Affected Product\n\nRUGGEDCOM APE1808 with Fortinet NGFW\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate Fortigate NGFW to V7.6.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-415 Double Free\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n2.3\n\nLOW\n\nCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported this vulnerability to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for\ncontrol systems security recommended practices\non the ICS webpage on\ncisa.gov/ics\n. Several CISA products detailing cyber defense best practices are available for reading and download, including\nImproving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies\n.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for\nproactive defense of ICS assets\n.\n\nAdditional mitigation guidance and recommended practices are publicly available on the ICS webpage at\ncisa.gov/ics\nin the technical information paper,\nICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies\n.\n\nOrganizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.\n\nAdvisory Conversion D…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-07","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028698Z","severity":"low","cvss_score":3.1,"epss":0.001,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":"fortinet","product":null,"vuln_id":"CVE-2026-106175","vuln_ids":["CVE-2026-106175"],"tags":[],"cluster_id":33,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/40","html":"https://vulnwatch.ve1ve2.com/item/40"}},{"id":39,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens Industrial Automation Software Products","summary":"View CSAF\n\nSummary\n\nOn October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as \"Node2Shell\" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact of various Siemens products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available.\n\nThe following versions of Siemens Industrial Automation Software Products are affected:\n\nCOMOS Walkinside vers:all/* (CVE-2026-111497)\n\ngDAP (gPROMS Digital Application Platform) vers:all/* ()\n\nProject Server Web Administration Tool vers:all/* (CVE-2026-111497)\n\nSIMATIC BRAUMAT vers:intdot/>=8.2.0.1|<8.2.0.5 (CVE-2026-111497)\n\nSIMATIC Profiling Tool vers:all/* (CVE-2026-111497)\n\nSIMATIC SISTAR vers:intdot/>=8.2.0.1|<8.2.0.5 (CVE-2026-111497)\n\nSIMATIC WinCC Companion vers:all/* (CVE-2026-111497)\n\nSIMATIC WinCC OA V3.20 vers:intdot/<3.20.17.1 (CVE-2026-111497)\n\nSIMATIC WinCC OA V3.21 vers:all/* (CVE-2026-111497)\n\nSIMATIC WinCC Runtime Professional vers:all/* (CVE-2026-111497)\n\nSIMATIC WinCC Unified for Industrial Edge vers:all/* (CVE-2026-111497)\n\nSIMATIC WinCC Unified PC Runtime vers:all/* (CVE-2026-111497)\n\nSIMATIC WinCC Unified SIQENCE vers:all/* (CVE-2026-111497)\n\nSIMATIC WinCC V7/V8 vers:all/* (CVE-2026-111497)\n\nTIA Administrator vers:all/* (CVE-2026-111497)\n\nUser Management Component (UMC) vers:all/* (CVE-2026-111497)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 9.8\n\nSiemens\n\nCOMOS Walkinside\n\n1 Vulnerability\n\nOut-of-bounds Write\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing, Food and Agriculture, Energy\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-111497\n\nA buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\n\nRead More\n\n15 Affected Products\n\nCOMOS Walkinside\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nMitigation\nTemporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC Runtime Professional\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nMitigation\nTemporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC Unified for Industrial Edge\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nMitigation\nTemporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC Unified PC Runtime\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nMitigation\nTemporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC Unified SIQENCE\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nMitigation\nTemporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC V7/V8\n\nProduct Statu…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-03","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028695Z","severity":"critical","cvss_score":9.2,"epss":0.99931,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-10","vendor":"Google","product":"Brotli","vuln_id":"CVE-2026-111497","vuln_ids":["CVE-2026-105482","CVE-2026-105483","CVE-2026-106069","CVE-2026-111497","GHSA-9V8H-QQGM-4M35"],"tags":[],"cluster_id":30,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/39","html":"https://vulnwatch.ve1ve2.com/item/39"}},{"id":38,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens SIMATIC","summary":"View CSAF\n\nSummary\n\nThe products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.\n\nThe following versions of Siemens SIMATIC are affected:\n\nSIMATIC BATCH V9.1 vers:all/* (CVE-2026-58114)\n\nSIMATIC Information Server 2020 vers:all/* (CVE-2026-58114)\n\nSIMATIC Information Server 2022 vers:all/* (CVE-2026-58114)\n\nSIMATIC PCS 7 V9.1 vers:all/* (CVE-2026-58114)\n\nSIMATIC Process Historian 2020 vers:all/* (CVE-2026-58114)\n\nSIMATIC Process Historian 2022 vers:all/* (CVE-2026-58114)\n\nSIMATIC WinCC Runtime Professional V17 vers:all/* (CVE-2026-58114)\n\nSIMATIC WinCC Runtime Professional V18 vers:all/* (CVE-2026-58114)\n\nSIMATIC WinCC Runtime Professional V19 vers:all/* (CVE-2026-58114)\n\nSIMATIC WinCC Runtime Professional V20 vers:all/* (CVE-2026-58114)\n\nSIMATIC WinCC Runtime Professional V21 vers:all/* (CVE-2026-58114)\n\nSIMATIC WinCC V7.5 vers:all/* (CVE-2026-58114)\n\nSIMATIC WinCC V8.0 vers:all/* (CVE-2026-58114)\n\nSIMATIC WinCC V8.1 vers:all/* (CVE-2026-58114)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 7.5\n\nSiemens\n\nSIMATIC BATCH V9.1\n\n1 Vulnerability\n\nWeak Authentication\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-58114\n\nAffected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.\n\nRead More\n\n14 Affected Products\n\nSIMATIC BATCH V9.1\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nCustomers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID\n\nNo fix planned\nCurrently no fix is planned\n\nSIMATIC WinCC Runtime Professional V20\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nCustomers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC Runtime Professional V21\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nCustomers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC V7.5\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nCustomers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC V8.0\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nCustomers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID\n\nNone available\nCurrently no fix is available\n\nSIMATIC WinCC V8.1\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nCustomers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID\n\nNone available\nCurrently no fix is available\n\nSIMATIC Information Server 2020\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nCustomers can manually configure the SQL Server Database for encrypting communication as described in https://support.i…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-08","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028693Z","severity":"unknown","cvss_score":null,"epss":0.00345,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-58114","vuln_ids":["CVE-2026-58114"],"tags":[],"cluster_id":32,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/38","html":"https://vulnwatch.ve1ve2.com/item/38"}},{"id":37,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens ROS#","summary":"View CSAF\n\nSummary\n\nROS# before version 2.3.1 contains a code injection vulnerability that could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program. Siemens has released a new version for ROS# and recommends to update to the latest version.\n\nThe following versions of Siemens ROS# are affected:\n\nROS# vers:intdot/<2.3.1 (CVE-2026-109097)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 8.2\n\nSiemens\n\nROS#\n\n1 Vulnerability\n\nImproper Control of Generation of Code ('Code Injection')\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-109097\n\nAffected systems do not properly escape text of message definition files. This could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program.\n\nRead More\n\n1 Affected Product\n\nROS# < V2.3.1\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V2.3.1 or later version\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-94 Improper Control of Generation of Code ('Code Injection')\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n8.2\n\nHIGH\n\nCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported this vulnerability to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for\ncontrol systems security recommended practices\non the ICS webpage on\ncisa.gov/ics\n. Several CISA products detailing cyber defense best practices are available for reading and download, including\nImproving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies\n.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for\nproactive defense of ICS assets\n.\n\nAdditional mitigation guidance and recommended practices are publicly available on the ICS webpage at\ncisa.gov/ics\nin the technical information paper,\nICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies\n.\n\nOrganizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.\n\nAdvisory Conversion Disclaimer\n\nThis ICSA is a verbatim…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-06","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028691Z","severity":"low","cvss_score":3.1,"epss":0.00121,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-109097","vuln_ids":["CVE-2026-109097"],"tags":[],"cluster_id":31,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/37","html":"https://vulnwatch.ve1ve2.com/item/37"}},{"id":36,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens Industrial Software Products","summary":"View CSAF\n\nSummary\n\nOn October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as \"Node2Shell\" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact of various Siemens software products. Please also have a look on following Software Field Bulletins: Teamcenter: https://support.sw.siemens.com/en-US/knowledge-base/PL8869204 Polarion: https://support.sw.siemens.com/en-US/knowledge-base/PL8869197 Manufacturing Operations Center (Opcenter) and Process Preparation X: https://support.sw.siemens.com/en-US/knowledge-base/PL8869211 Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.\n\nThe following versions of Siemens Industrial Software Products are affected:\n\nHyperLynx vers:all/* (CVE-2026-111497)\n\nInnexis Architecture Native Acceleration 2026 vers:all/* (CVE-2026-111497)\n\nInsights Hub vers:all/* (CVE-2026-111497)\n\nOpcenter Connect Electronics vers:all/* (CVE-2026-111497)\n\nOpcenter Connect MOM vers:all/* (CVE-2026-111497)\n\nOpcenter Execution Core vers:all/* (CVE-2026-111497)\n\nOpcenter Execution Discrete vers:all/* (CVE-2026-111497)\n\nOpcenter Execution Foundation vers:all/* (CVE-2026-111497)\n\nOpcenter Execution Pharma vers:all/* (CVE-2026-111497)\n\nOpcenter Execution Process vers:all/* (CVE-2026-111497)\n\nOpcenter Intelligence vers:all/* (CVE-2026-111497)\n\nOpcenter Intra Plant Logistics vers:all/* (CVE-2026-111497)\n\nOpcenter Quality vers:all/* (CVE-2026-111497)\n\nOpcenter RDnL vers:all/* (CVE-2026-111497)\n\nOpcenter X vers:all/* (CVE-2026-111497)\n\nPADS Pro Essentials vers:all/* (CVE-2026-111497)\n\nPADS Pro Student Edition vers:all/* (CVE-2026-111497)\n\nPADS Professional vers:all/* (CVE-2026-111497)\n\nPAVE360 Automotive 2026 vers:all/* (CVE-2026-111497)\n\nProcess Preparation X vers:all/* (CVE-2026-111497)\n\nSimcenter Executable Digital Twin vers:all/* (CVE-2026-111497)\n\nSimcenter Studio vers:all/* (CVE-2026-111497)\n\nTeamcenter V2412 vers:all/* (CVE-2026-111497)\n\nTeamcenter V2506 vers:all/* (CVE-2026-111497)\n\nTeamcenter V2512 vers:all/* (CVE-2026-111497)\n\nTeamcenter V2606 vers:all/* (CVE-2026-111497)\n\nXpedition Designer vers:all/* (CVE-2026-111497)\n\nXpedition Enterprise vers:all/* (CVE-2026-111497)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 9.8\n\nSiemens\n\nHyperLynx, Innexis, Insights, Opcenter, PADS, PAVE360, Process Preparation, Simcenter, Teamcenter, Xpedition\n\n1 Vulnerability\n\nOut-of-bounds Write\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-111497\n\nA buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\n\n28 Affected Products\n\nOpcenter Execution Core\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nThe vulnerability can be mitigated on the IIS Reverse Proxy. Please see https://support.sw.siemens.com/en-US/knowledge-base/PL8869211\n\nNone available\nCurrently no fix is available\n\nOpcenter Execution Discrete\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nThe vulnerability can be mitigated on the IIS Reverse Proxy. Please see https://support.sw.siemens.com/en-US/knowledge-base/PL8869211\n\nNone available\nCurrently no fix is available\n\nOpcenter Execution Foundation\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nThe vulnerability can be mitigat…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-04","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028688Z","severity":"critical","cvss_score":9.2,"epss":0.99931,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-10","vendor":"Google","product":"Brotli","vuln_id":"CVE-2026-111497","vuln_ids":["CVE-2026-105482","CVE-2026-105483","CVE-2026-106069","CVE-2026-111497","GHSA-9V8H-QQGM-4M35"],"tags":[],"cluster_id":30,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/36","html":"https://vulnwatch.ve1ve2.com/item/36"}},{"id":35,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Critical Java Vulnerability Requires Immediate Patching","summary":"Purpose\n\nCISA strongly urges organizations to immediately patch the recently disclosed Oracle Java vulnerability\nCVE-2026-114938\n. This critical memory-corruption vulnerability, known as “Java4Shell,” affects the Base64 decoder of the x86-64 HotSpot Java Virtual Machine (JVM), which is part of the Java Development Kit (JDK). Specially crafted Base64 input could crash the JVM and allow for unauthenticated remote code execution.\n\nActions to take\n\nCISA urges organizations to take the following actions:\n\nIdentify affected Java installations. Review your software inventory for JDKs and Java runtimes, including those bundled with third-party applications or included in container images and appliances.\nNote:\nJDKs and Java runtimes may not appear as separate entries in software inventories.\n\nApply relevant Java and vendor patches as soon as they are available, prioritizing internet-facing systems.\n\nIf immediate patching is not feasible, implement temporary compensating controls, such as restricting and validating Base64 input at the application boundary, enforcing input-size limits, and limiting unauthenticated access.\n\nReview\nOracle’s security advisory\nfor guidance on patching and affected products and versions.\n\nMonitor for indicators of suspicious activity, including rogue runtimes, unexpected JVM crashes, and suspicious Java processes.\n\nResources\n\nCISA urges network defenders to review the following resource and apply necessary updates:\n\nVendor Guidance\n\nOracle’s Security Advisory:\nCritical Security Patch Update – November 2026\n\nDisclaimer\n\nThe information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA.\n\nAcknowledgements\n\nThe Canadian Centre for Cyber Security (Cyber Centre) contributed to this Alert.","url":"https://cisa.gov/news-events/alerts/2026/11/17/critical-java-vulnerability-requires-immediate-patching","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028686Z","severity":"critical","cvss_score":8.1,"epss":0.45636,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":"oracle","product":null,"vuln_id":"CVE-2026-114938","vuln_ids":["CVE-2026-114938"],"tags":[],"cluster_id":5,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/35","html":"https://vulnwatch.ve1ve2.com/item/35"}},{"id":34,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens .NET Client Library for SIMATIC S7 Webserver API","summary":"View CSAF\n\nSummary\n\n.NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version.\n\nThe following versions of Siemens .NET Client Library for SIMATIC S7 Webserver API are affected:\n\n.NET Client Library for SIMATIC S7 Webserver API vers:intdot/<3.3.61, vers:intdot/<3.3.62 (CVE-2026-85114, CVE-2026-85115)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 7.5\n\nSiemens\n\n.NET Client Library for SIMATIC S7 Webserver API\n\n2 Vulnerabilities\n\nImproper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Generation of Error Message Containing Sensitive Information\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nExpand All +\n\nCVE-2026-85114\n\nAffected applications do not properly validate filenames received from remote servers during ticket downloads. This could allow an attacker who can manipulate the ticket response to write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application.\n\nRead More\n\n1 Affected Product\n\n.NET Client Library for SIMATIC S7 Webserver API < V3.3.61\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V3.3.61 or later version\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n7.5\n\nHIGH\n\nCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\n\nView CVE Details\n\nCVE-2026-85115\n\nAffected applications do not properly redact PLC restore passwords from HTTP error exception messages. This could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC.\n\nRead More\n\n2 Affected Products\n\n.NET Client Library for SIMATIC S7 Webserver API < V3.3.61\n\nProduct Status: known_affected\n\nRemediations\n\n.NET Client Library for SIMATIC S7 Webserver API < V3.3.62\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V3.3.62 or later version\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-209 Generation of Error Message Containing Sensitive Information\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n5.5\n\nMEDIUM\n\nCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported these vulnerabilities to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them f…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-02","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028684Z","severity":"low","cvss_score":3.1,"epss":0.0033,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-85114","vuln_ids":["CVE-2026-85114","CVE-2026-85115"],"tags":[],"cluster_id":28,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/34","html":"https://vulnwatch.ve1ve2.com/item/34"}},{"id":33,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens Mendix Studio Pro","summary":"View CSAF\n\nSummary\n\nMendix Studio Pro contains multiple vulnerabilities in the MCP Server, that could allow an attacker with network access to interact with the server remotely or trick a user's browser into sending unauthorized requests, potentially leading to unauthorized data access, tool execution, or system compromise. Siemens has released new versions for the affected products and recommends to update to the latest versions.\n\nThe following versions of Siemens Mendix Studio Pro are affected:\n\nMendix Studio Pro 11 vers:intdot/>=11.15.0|<11.16.0 (CVE-2026-112136, CVE-2026-112137)\n\nMendix Studio Pro 11.12 vers:intdot/>=11.12.6|<11.12.7 (CVE-2026-112136, CVE-2026-112137)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 8.8\n\nSiemens\n\nMendix Studio Pro 11\n\n2 Vulnerabilities\n\nBinding to an Unrestricted IP Address, Cross-Site Request Forgery (CSRF)\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing, Energy\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nExpand All +\n\nCVE-2026-112136\n\nThe affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.\n\nRead More\n\n2 Affected Products\n\nMendix Studio Pro 11 >= V11.15.0 < V11.16.0\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nMaintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules.\n\nVendor fix\nUpdate to V11.16.0 or later version\n\nMendix Studio Pro 11.12 >= V11.12.6 < V11.12.7\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nMaintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules.\n\nVendor fix\nUpdate to V11.12.7 or later version\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-1327 Binding to an Unrestricted IP Address\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n8.8\n\nHIGH\n\nCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\n\nView CVE Details\n\nCVE-2026-112137\n\nThe affected products MCP Server does not properly validate Content-Type and Origin headers on incoming HTTP requests, leaving it vulnerable to Cross-Site Request Forgery (CSRF). This could allow a malicious web page to trick a user's browser into sending unauthorized requests and executing unintended actions on the local MCP Server.\n\nRead More\n\n4 Affected Products\n\nMendix Studio Pro 11 >= V11.15.0 < V11.16.0\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nUtilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).\n\nVendor fix\nUpdate to V11.16.0 or later version\n\nMendix Studio Pro 11.12 >= V11.12.6 < V11.12.7\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nUtilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).\n\nVendor fix\nUpdate to V11.12.7 or later version\n\nMendix Studio Pro 11 >= V11.15.0 < V11.16.0\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nUtilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block extern…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-05","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028680Z","severity":"low","cvss_score":3.1,"epss":0.00304,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-112136","vuln_ids":["CVE-2026-112136","CVE-2026-112137"],"tags":[],"cluster_id":26,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/33","html":"https://vulnwatch.ve1ve2.com/item/33"}},{"id":32,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Dorsett Controls InfoScan","summary":"View CSAF\n\nSummary\n\nSuccessful exploitation of these vulnerabilities could allow an attacker to retrieve sensitive system information, access application data without authorization, recover stored credentials, or intercept and manipulate network communications.\n\nThe following versions of Dorsett Controls InfoScan are affected:\n\nInfoScan <=1.45.0 (CVE-2026-117659, CVE-2026-120157, CVE-2026-120255, CVE-2026-120260, CVE-2026-120271, CVE-2026-120298)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 8.1\n\nDorsett Controls\n\nInfoScan\n\n5 Vulnerabilities\n\nImproper Certificate Validation, Exposure of Sensitive System Information to an Unauthorized Control Sphere, Use of Hard-coded Cryptographic Key, Missing Authentication for Critical Function, Generation of Error Message Containing Sensitive Information\n\nBackground\n\nCritical Infrastructure Sectors:\nWater and Wastewater Systems\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nUnited States\n\nVulnerabilities\n\nExpand All +\n\nCVE-2026-117659\n\nThe InfoScan Electron desktop client improperly handles TLS certificate errors by accepting certificates without validating their trustworthiness. The client also configures Electron with nodeIntegration enabled, contextIsolation disabled, and webSecurity disabled. These settings weaken the client’s security boundaries. An attacker who is able to intercept or manipulate network communications may be able to present an untrusted certificate without the application rejecting the connection.\n\nRead More\n\n1 Affected Product\n\nDorsett Controls InfoScan <=1.45.0\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nDorsett Controls recommends updating affected versions of InfoScan to v1.46 or higher. To install the security patch, user administrators will need to log in to InfoScan and select System Maintenance from the menu. Once the System Maintenance application is open, select Check for Updates, and click the Install Now button in the Ready To Install section. If you are an offline customer (InfoScan has no internet access), you will need to download the update from the Dorsett Controls Customer Portal by selecting the InfoScan Update tile, downloading the update, and following the instructions listed on the portal.\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-295 Improper Certificate Validation\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n8.1\n\nHIGH\n\nCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N\n\n4.0\n\n8.5\n\nHIGH\n\nCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N\n\nView CVE Details\n\nCVE-2026-120157\n\nThe publicly distributed InfoScan Electron installer contains configuration files identifying hostnames associated with customer installations and internal development, testing, and database infrastructure. An individual who obtains and inspects the installer can extract these hostnames without authenticating to the affected systems.\n\nRead More\n\n2 Affected Products\n\nDorsett Controls InfoScan <=1.45.0\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nDorsett Controls recommends updating affected versions of InfoScan to v1.46 or higher. To install the security patch, user administrators will need to log in to InfoScan and select System Maintenance from the menu. Once the System Maintenance application is open, select Check for Updates, and click the Install Now button in the Ready To Install section. If you are an offline customer (InfoScan has no internet access), you will need to download the update from the Dorsett Controls Customer Portal by selecting the InfoScan Update tile, downloading the update, and following the instructions listed on the portal.\n\nDorsett Controls InfoScan <=1.45.0\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nDorsett Controls recommends updating affected versions of InfoScan to v1.46 or higher. To install the security patch, user administrators will need to log in to InfoScan and select System Maintenance from the menu. Once the System Maintenance application is open, select Check for Update…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-01","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028677Z","severity":"high","cvss_score":8.5,"epss":0.00401,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-117659","vuln_ids":["CVE-2026-117659","CVE-2026-120157","CVE-2026-120255","CVE-2026-120260","CVE-2026-120271","CVE-2026-120298"],"tags":[],"cluster_id":20,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/32","html":"https://vulnwatch.ve1ve2.com/item/32"}},{"id":31,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens Simcenter Femap","summary":"View CSAF\n\nSummary\n\nSimcenter Femap is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.\n\nThe following versions of Siemens Simcenter Femap are affected:\n\nSimcenter Femap vers:intdot/<2606.0002 (CVE-2026-64629)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 7.8\n\nSiemens\n\nSimcenter Femap\n\n1 Vulnerability\n\nOut-of-bounds Read\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-64629\n\nThe affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.\n\nRead More\n\n1 Affected Product\n\nSimcenter Femap < V2606.0002\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V2606.0002 or later version\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-125 Out-of-bounds Read\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n7.8\n\nHIGH\n\nCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported this vulnerability to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for\ncontrol systems security recommended practices\non the ICS webpage on\ncisa.gov/ics\n. Several CISA products detailing cyber defense best practices are available for reading and download, including\nImproving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies\n.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for\nproactive defense of ICS assets\n.\n\nAdditional mitigation guidance and recommended practices are publicly available on the ICS webpage at\ncisa.gov/ics\nin the technical information paper,\nICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies\n.\n\nOrganizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.\n\nAdvisory Conversion Disclaimer\n\nThis ICSA is a verbatim republication of Siemens Produc…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-10","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028674Z","severity":"low","cvss_score":3.1,"epss":0.00168,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-64629","vuln_ids":["CVE-2026-64629"],"tags":[],"cluster_id":19,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/31","html":"https://vulnwatch.ve1ve2.com/item/31"}},{"id":44,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"CISA Adds Two Known Exploited Vulnerabilities to Catalog","summary":"CISA has added two new vulnerabilities to its\nKnown Exploited Vulnerabilities (KEV) Catalog\n, based on evidence of active exploitation.\n\nCVE-2026-114713\nUnrealIRCd Improper Neutralization of Delimiters Vulnerability\n\nCVE-2026-123039\nCheck Point Multiple Products Incorrect Permission Assignment for Critical Resource Vulnerability\n\nThese types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.\n\nBinding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk\nestablishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.\n\nWhile BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of\nKEV Catalog vulnerabilities\n. CISA will continue to add vulnerabilities to the catalog that meet the\nspecified criteria\n.\n\nAware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s\nKEV Nomination Form\n. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.","url":"https://cisa.gov/news-events/alerts/2026/11/13/cisa-adds-two-known-exploited-vulnerabilities-catalog","published_at":"2026-11-13T12:00:00Z","updated_at":"2026-11-13T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028711Z","severity":"high","cvss_score":7.8,"epss":0.03269,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-16","vendor":"UnrealIRCd","product":"UnrealIRCd","vuln_id":"CVE-2026-114713","vuln_ids":["CVE-2026-114713","CVE-2026-123039"],"tags":[],"cluster_id":37,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/44","html":"https://vulnwatch.ve1ve2.com/item/44"}},{"id":49,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens Industrial Edge Management","summary":"View CSAF\n\nSummary\n\nSiemens is currently assessing the impact of Node2Shell (CVE-2026-111497) on Industrial Edge. Please check your Industrial Edge Management (IEM) setup: - No Management Applications installed: No action is required. Although the affected Brotli library is included in the IEM software stack, the affected functionality is not used or exposed. The same applies to IEDK. - Management Applications installed: Follow the specific mitigations until a fix is available. - Device Applications installed: Follow the specific mitigations until a fix is available. For Siemens-managed services, Industrial Edge Hub and Industrial Edge Management Cloud, appropriate Firewall/WAF protection has already been implemented. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available.\n\nThe following versions of Siemens Industrial Edge Management are affected:\n\nCloud Connector Configurator vers:intdot/<1.24.3 (CVE-2026-111497)\n\nCommon Configurator (CC on IEM) vers:all/* (CVE-2026-111497)\n\nCommon Configurator on Device (CC on Edge) vers:all/* (CVE-2026-111497)\n\nData Flow Monitoring vers:intdot/<3.0.18 (CVE-2026-111497)\n\nDatabus Configurator vers:intdot/<4.0.1 (CVE-2026-111497)\n\nDataXess Configurator vers:intdot/<1.5.7 (CVE-2026-111497)\n\nEdge OPC UA Server Configurator vers:intdot/<2.3.10 (CVE-2026-111497)\n\nFlow Creator Configurator vers:intdot/<1.15.1 (CVE-2026-111497)\n\nIndustrial Edge Hub vers:all/* (CVE-2026-111497)\n\nIndustrial Edge Management Cloud vers:all/* (CVE-2026-111497)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 9.8\n\nSiemens\n\nCloud Connector Configurator\n\n1 Vulnerability\n\nOut-of-bounds Write\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-111497\n\nA buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\n\nRead More\n\n10 Affected Products\n\nCloud Connector Configurator < V1.24.3\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V1.24.3 or later version\n\nIndustrial Edge Management Cloud\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nVulnerability fixed on central cloud service starting 2026-10-28; no user actions necessary\n\nCommon Configurator (CC on IEM)\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nUninstall all Management Applications and protect your IEM instance with a Firewall/WAF until a fix is available\n\nNone available\nCurrently no fix is available\n\nCommon Configurator on Device (CC on Edge)\n\nProduct Status: known_affected\n\nRemediations\n\nMitigation\nStop Common Configurator on Device (CC on Edge) until a fix is available\n\nNone available\nCurrently no fix is available\n\nData Flow Monitoring < V3.0.18\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V3.0.18 or later version\n\nDatabus Configurator < V4.0.1\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V4.0.1 or later version\n\nDataXess Configurator < V1.5.7\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V1.5.7 or later version\n\nEdge OPC UA Server Configurator < V2.3.10\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V2.3.10 or later version\n\nFlow Creator Configurator < V1.15.1\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V1.15.1 or later version\n\nIndustrial Edge Hub\n\nProduct Status: known_affected\n\nRemediations\n\nVendor…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-316-03","published_at":"2026-11-12T12:00:00Z","updated_at":"2026-11-12T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028723Z","severity":"critical","cvss_score":9.2,"epss":0.99931,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-10","vendor":"Google","product":"Brotli","vuln_id":"CVE-2026-111497","vuln_ids":["CVE-2026-105482","CVE-2026-105483","CVE-2026-106069","CVE-2026-111497","GHSA-9V8H-QQGM-4M35"],"tags":[],"cluster_id":30,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/49","html":"https://vulnwatch.ve1ve2.com/item/49"}},{"id":48,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens Desigo, Gridscale","summary":"View CSAF\n\nSummary\n\nOn October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as \"Node2Shell\" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact of various Siemens software products. Siemens has released new versions for the affected products and recommends to update to the latest versions.\n\nThe following versions of Siemens Desigo, Gridscale are affected:\n\nDesigo CC family V8 vers:all/* (CVE-2026-111497)\n\nDesigo CC family V9 vers:all/* (CVE-2026-111497)\n\nGridscale X DSA vers:intdot/>=5.3|<5.4 (CVE-2026-111497)\n\nGridscale X PSS®E vers:intdot/<36.8.0 (CVE-2026-111497)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 9.8\n\nSiemens\n\nDesigo CC family V8\n\n1 Vulnerability\n\nOut-of-bounds Write\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing, Energy, Information Technology\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-111497\n\nA buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\n\nRead More\n\n4 Affected Products\n\nDesigo CC family V8\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nVendor fix\nInstall the latest .NET security updates via Windows Update.\n\nDesigo CC family V9\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nVendor fix\nInstall the latest .NET security updates via Windows Update.\n\nGridscale X DSA >= V5.3 < V5.4\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nVendor fix\nUpdate to V5.4 or later version\n\nGridscale X PSS®E < V36.8.0\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nVendor fix\nUpdate to V36.8.0 or later version\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-787 Out-of-bounds Write\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n9.8\n\nCRITICAL\n\nCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported this vulnerability to CISA.\n\nGeneral Recommendations\n\nOperators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at:\nhttps://www.siemens.com/gridsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-316-02","published_at":"2026-11-12T12:00:00Z","updated_at":"2026-11-12T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028719Z","severity":"critical","cvss_score":9.2,"epss":0.99931,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-10","vendor":"Google","product":"Brotli","vuln_id":"CVE-2026-111497","vuln_ids":["CVE-2026-105482","CVE-2026-105483","CVE-2026-106069","CVE-2026-111497","GHSA-9V8H-QQGM-4M35"],"tags":[],"cluster_id":30,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/48","html":"https://vulnwatch.ve1ve2.com/item/48"}},{"id":47,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens RUGGEDCOM APE1808","summary":"View CSAF\n\nSummary\n\nPalo Alto Networks has published\ninformation\non a vulnerability in PAN-OS related to the Node2Shell vulnerability. This advisory lists the related Siemens Industrial products affected by this vulnerability. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications.\n\nThe following versions of Siemens RUGGEDCOM APE1808 are affected:\n\nRUGGEDCOM APE1808 vers:all/* (CVE-2026-111497)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 9.8\n\nSiemens\n\nRUGGEDCOM APE1808\n\n1 Vulnerability\n\nOut-of-bounds Write\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-111497\n\nA buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\n\nRead More\n\n1 Affected Product\n\nRUGGEDCOM APE1808 with Palo Alto Networks PAN-OS\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpgrade to corresponding available PAN-OS version. Contact customer support to receive additional patch and update information.\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-787 Out-of-bounds Write\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n9.8\n\nCRITICAL\n\nCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported this vulnerability to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for Industrial Security (\nhttps://www.siemens.com/cert/operational-guidelines-industrial-security\n), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at:\nhttps://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT:\nhttps://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on:\nhttps://www.siemens.com/productcert/terms-of-use\n.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for\ncontrol systems security recommended practices\non the ICS webpage on\ncisa.gov/ics\n. Several CISA products detailing cyber defense best practices are available for reading and download, including\nImproving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies\n.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for\nproactive defense of ICS assets\n.\n\nAdditional mitigation guidance and recommended practices are publicly available on th…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-316-04","published_at":"2026-11-12T12:00:00Z","updated_at":"2026-11-12T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028717Z","severity":"critical","cvss_score":9.2,"epss":0.99931,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-10","vendor":"paloalto","product":"Brotli","vuln_id":"CVE-2026-111497","vuln_ids":["CVE-2026-105482","CVE-2026-105483","CVE-2026-106069","CVE-2026-111497","GHSA-9V8H-QQGM-4M35"],"tags":[],"cluster_id":30,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/47","html":"https://vulnwatch.ve1ve2.com/item/47"}},{"id":46,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens RUGGEDCOM APE1808","summary":"View CSAF\n\nSummary\n\nPalo Alto Networks has published\ninformation\non vulnerabilities in PAN-OS related to PHP2Shell vulnerabilities. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications.\n\nThe following versions of Siemens RUGGEDCOM APE1808 are affected:\n\nRUGGEDCOM APE1808 vers:all/* (CVE-2026-109618, CVE-2026-109619)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 9.8\n\nSiemens\n\nRUGGEDCOM APE1808\n\n1 Vulnerability\n\nUse After Free\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nExpand All +\n\nCVE-2026-109618\n\nPHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).\n\nRead More\n\n1 Affected Product\n\nRUGGEDCOM APE1808 with Palo Alto Networks PAN-OS (10.2 All, 11.1 All, 11.2 All, 12.1 All, 12.2 All)\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpgrade to corresponding available PAN-OS version. Contact customer support to receive additional patch and update information.\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-416 Use After Free\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n9.8\n\nCRITICAL\n\nCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\n\nView CVE Details\n\nCVE-2026-109619\n\nPHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).\n\nRead More\n\n2 Affected Products\n\nRUGGEDCOM APE1808 with Palo Alto Networks PAN-OS (10.2 All, 11.1 All, 11.2 All, 12.1 All, 12.2 All)\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpgrade to corresponding available PAN-OS version. Contact customer support to receive additional patch and update information.\n\nRUGGEDCOM APE1808 with Palo Alto Networks PAN-OS (10.2 All, 11.1 All, 11.2 All, 12.1 All, 12.2 All)\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpgrade to corresponding available PAN-OS version. Contact customer support to receive additional patch and update information.\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-416 Use After Free\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n8.1\n\nHIGH\n\nCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported these vulnerabilities to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (\nhttps://www.siemens.com/cert/operational-guidelines-industrial-security\n), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at:\nhttps://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT:\nhttps://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on:\nhttps://www.siemens.com/productcert/terms-of-use\n.\n\nRecommended P…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-316-05","published_at":"2026-11-12T12:00:00Z","updated_at":"2026-11-12T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028715Z","severity":"critical","cvss_score":9.2,"epss":0.99999,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-10-29","vendor":"paloalto","product":"PHP","vuln_id":"CVE-2026-109618","vuln_ids":["CVE-2026-109618","CVE-2026-109619","GHSA-6WMF-4RV5-P3RP","GHSA-W8HW-W9FX-J79W"],"tags":[],"cluster_id":39,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/46","html":"https://vulnwatch.ve1ve2.com/item/46"}},{"id":45,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens Building Automation and Energy Products","summary":"View CSAF\n\nSummary\n\nOn October 21, 2026, the PHP project and security researchers disclosed two critical, unauthenticated remote code execution vulnerabilities in the core PHP language runtime known as \"php2shell\" (tracked as CVE-2026-109618 and CVE-2026-109619). This advisory covers the status of impact of various Siemens software products. As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines, and to follow the recommendations in the product manuals. Siemens is actively monitoring the situation and assessing the implications of these vulnerabilities on our portfolio. Because this evaluation is ongoing, our findings are subject to change as new technical details and vendor updates emerge. We will publish updated findings, guidance, and remediation recommendations as soon as they become available. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends mitigations for products where fixes are not or not yet available.\n\nThe following versions of Siemens Building Automation and Energy Products are affected:\n\nAMIS TS vers:all/* (CVE-2026-109618, CVE-2026-109619)\n\nblueplanet 360 NX3 M6 WM OD IISX vers:all/* (CVE-2026-109618, CVE-2026-109619)\n\nblueplanet 360 NX3 M6 WM OD IISX - S vers:all/* (CVE-2026-109618, CVE-2026-109619)\n\nEnergy Engage V2.0SP9 vers:all/* (CVE-2026-109618, CVE-2026-109619)\n\nEnergy Engage V3.1SP1 vers:all/* (CVE-2026-109618, CVE-2026-109619)\n\nHeliox Rapid vers:all/* ()Local Monitoring bt-monitoring-vm vers:intdot/<20261103 (CVE-2026-109618, CVE-2026-109619)\n\nSpectrum Power 3 vers:all/* (CVE-2026-109619)\n\nSpectrum Power 4 vers:all/*, vers:all/*, vers:all/* (CVE-2026-109618, CVE-2026-109619, CVE-2026-109618, CVE-2026-109619, CVE-2026-109618, CVE-2026-109619)\n\nSpectrum Power 7 vers:all/* (CVE-2026-109618, CVE-2026-109619)\n\nSpectrum Power TG vers:all/* (CVE-2026-109618, CVE-2026-109619)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 9.8\n\nSiemens\n\nAMIS TS\n\n1 Vulnerability\n\nUse After Free\n\nBackground\n\nCritical Infrastructure Sectors:\nEnergy\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nExpand All +\n\nCVE-2026-109618\n\nPHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).\n\nRead More\n\n11 Affected Products\n\nAMIS TS\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nNone available\nCurrently no fix is available\n\nblueplanet 360 NX3 M6 WM OD IISX\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nNone available\nCurrently no fix is available\n\nEnergy Engage V2.0SP9\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nNo fix planned\nCurrently no fix is planned\n\nEnergy Engage V3.1SP1\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nVendor fix\nUpgrade PHP version to V8.1.34 release 6\n\nblueplanet 360 NX3 M6 WM OD IISX - S\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nNone available\nCurrently no fix is available\n\nLocal Monitoring bt-monitoring-vm < V20261103\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nVendor fix\nUpdate to V20261103 or later version\n\nSpectrum Power 4 using Nagios or Zabbix\n\nProduct Status: known_affected, known_not_affected\n\nRemediations\n\nNone available\nCurrently no fix is available\n\nSpectrum Power 4 with Web Office Portal V3.0, V3.1 and V3.2\n\nProduct Status: known_affected, known…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-316-01","published_at":"2026-11-12T12:00:00Z","updated_at":"2026-11-12T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028713Z","severity":"critical","cvss_score":9.2,"epss":0.99999,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-10-29","vendor":"php","product":"PHP","vuln_id":"CVE-2026-109618","vuln_ids":["CVE-2026-109618","CVE-2026-109619","GHSA-6WMF-4RV5-P3RP","GHSA-W8HW-W9FX-J79W"],"tags":[],"cluster_id":39,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/45","html":"https://vulnwatch.ve1ve2.com/item/45"}},{"id":50,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"CISA Adds Six Known Exploited Vulnerabilities to Catalog","summary":"CISA has added six new vulnerabilities to its\nKnown Exploited Vulnerabilities (KEV) Catalog\n, based on evidence of active exploitation.\n\nCVE-2026-20320\nCisco BroadWorks Improper Restriction of XML External Entity Reference Vulnerability\n\nCVE-2026-111560\nBarracuda Networks Multiple Products OS Command Injection Vulnerability\n\nCVE-2026-111793\nOpenwave Messaging Limited Webtop Media Transcoder Incorrect Resource Transfer Between Spheres Vulnerability\n\nCVE-2026-116606\nBarracuda Networks Email Security Gateway (ESG) Authentication Bypass Using an Alternate Path or Channel Vulnerability\n\nCVE-2026-124194\nMicrosoft Office Outlook Missing User Interaction for Potentially Unsafe Action Vulnerability\n\nCVE-2026-125350\nGoogle Chromium Use-After-Free Vulnerability\n\nThese types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.\n\nBinding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk\nestablishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.\n\nWhile BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of\nKEV Catalog vulnerabilities\n. CISA will continue to add vulnerabilities to the catalog that meet the\nspecified criteria\n.\n\nAware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s\nKEV Nomination Form\n. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.","url":"https://cisa.gov/news-events/alerts/2026/11/10/cisa-adds-six-known-exploited-vulnerabilities-catalog","published_at":"2026-11-10T12:00:00Z","updated_at":"2026-11-10T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028727Z","severity":"critical","cvss_score":9.3,"epss":0.7452,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-13","vendor":"cisco","product":"BroadWorks","vuln_id":"CVE-2026-20320","vuln_ids":["CVE-2026-111560","CVE-2026-111793","CVE-2026-116606","CVE-2026-124194","CVE-2026-125350","CVE-2026-20320"],"tags":[],"cluster_id":41,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/50","html":"https://vulnwatch.ve1ve2.com/item/50"}},{"id":51,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"CISA Adds Four Known Exploited Vulnerabilities to Catalog","summary":"CISA has added four new vulnerabilities to its\nKnown Exploited Vulnerabilities (KEV) Catalog\n, based on evidence of active exploitation.\n\nCVE-2026-102895\nGPUStack Improper Authentication Vulnerability\n\nCVE-2026-116779\nSignalWire FreeSwitch Code Injection Vulnerability\n\nCVE-2026-123158\nOpenBSD OpenSSH Unexpected Status Code or Return Value Vulnerability\n\nCVE-2026-123218\nIBM Aspera Faspex Incorrect Authorization Vulnerability\n\nThese types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.\n\nBinding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk\nestablishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.\n\nWhile BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of\nKEV Catalog vulnerabilities\n. CISA will continue to add vulnerabilities to the catalog that meet the\nspecified criteria\n.\n\nAware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s\nKEV Nomination Form\n. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.","url":"https://cisa.gov/news-events/alerts/2026/11/09/cisa-adds-four-known-exploited-vulnerabilities-catalog","published_at":"2026-11-09T12:00:00Z","updated_at":"2026-11-09T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028729Z","severity":"unknown","cvss_score":null,"epss":0.8768,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-12","vendor":"openssh","product":"GPUStack","vuln_id":"CVE-2026-102895","vuln_ids":["CVE-2026-102895","CVE-2026-116779","CVE-2026-123158","CVE-2026-123218"],"tags":[],"cluster_id":47,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/51","html":"https://vulnwatch.ve1ve2.com/item/51"}},{"id":52,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"CISA Adds One Known Exploited Vulnerability to Catalog","summary":"CISA has added one new vulnerability to its\nKnown Exploited Vulnerabilities (KEV) Catalog\n, based on evidence of active exploitation.\n\nCVE-2026-19868\nSonicWall SonicOS SSLVPN Use of Single-factor Authentication Vulnerability\n\nThis type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.\n\nBinding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk\nestablishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.\n\nWhile BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of\nKEV Catalog vulnerabilities\n. CISA will continue to add vulnerabilities to the catalog that meet the\nspecified criteria\n.\n\nAware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s\nKEV Nomination Form\n. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.","url":"https://cisa.gov/news-events/alerts/2026/11/06/cisa-adds-one-known-exploited-vulnerability-catalog","published_at":"2026-11-06T12:00:00Z","updated_at":"2026-11-06T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028732Z","severity":"unknown","cvss_score":null,"epss":0.0804,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-20","vendor":"SonicWall","product":"SonicOS SSLVPN","vuln_id":"CVE-2026-19868","vuln_ids":["CVE-2026-19868"],"tags":[],"cluster_id":50,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/52","html":"https://vulnwatch.ve1ve2.com/item/52"}},{"id":54,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Post-Quantum Questions to Ask Your Vendors","summary":"CISA, the Australian Signals Directorate’s Australian Cyber Security Centre (ASD’s ACSC) and the National Security Agency (NSA) released joint guidance and an accompanying quick-reference list to help organizations assess vendor readiness for transitioning to post-quantum cryptography (PQC). As quantum computing advances, widely used public-key cryptography will become vulnerable to compromise from cryptographically relevant quantum computers (CRQCs). To protect their systems and data, organizations must plan for and transition to PQC—which includes algorithms capable of withstanding both classical computing and quantum-enabled threats—before CRQCs become available.\n\nMany organizations rely on third-party vendors for managed services, cloud capabilities, and other cryptography-dependent products and services. Cryptography is also embedded in systems and devices that are difficult to update, tied to long asset lifecycles, and require vendor support or replacement—such as industrial control systems and Internet of Things (IoT) devices. Reliance on vendors means that effective PQC transition depends on vendor readiness, and early, structured engagement with these vendors is critical to planning efforts.\n\nOrganizations can use the vendor-neutral questions outlined in this guidance to determine whether a vendor understands quantum-related risks, maintains transparency over its cryptographic implementations, and supports a secure, cost-effective and timely transition to PQC.\n\nVisit CISA’s\nPQC Initiative page\nfor additional resources.","url":"https://cisa.gov/resources-tools/resources/post-quantum-questions-ask-your-vendors","published_at":"2026-11-05T12:00:00Z","updated_at":"2026-11-05T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028736Z","severity":"unknown","cvss_score":null,"epss":null,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":null,"vuln_ids":[],"tags":[],"cluster_id":null,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/54","html":"https://vulnwatch.ve1ve2.com/item/54"}},{"id":53,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"US Government Partners Urge Hardening Industrial Refrigeration and Cold Chain Monitoring Systems","summary":"Overview\n\nThe Cybersecurity and Infrastructure Security Agency (CISA), Federal Bureau of Investigation (FBI), Health and Human Services (HHS), U.S. Department of Agriculture (USDA), and the Department of Transportation (DoT)—hereafter referred to as “the authoring organizations”—are aware of malicious cyber activity targeting industrial refrigeration and cold chain monitoring systems globally. Organizations in the\nHealthcare and Public Health\n,\nChemical\n,\nFood and Agriculture\n, and\nTransportation Systems\nSectors widely use these systems, including in refrigerated transport services, for automated and remote monitoring of temperatures, continuous temperature logging, defrost cycle management, and energy optimization.\n\nThe authoring organizations urge owners and operators to defend against this activity by using strong authentication, keeping systems updated, identifying any systems that are accessible from the internet, removing unnecessary remote access, and securing any necessary remote access.\n\nThreat\n\nThe authoring organizations are aware of malicious cyber actors targeting electronic temperature controllers and commercial refrigeration controllers in retail grocery and cold storage facilities. The actors may exploit vulnerabilities or weaknesses in unpatched or internet-accessible controllers to remotely alter settings and force units into continuous heating and defrost cycles, which can cause widespread inventory loss and equipment hazards.\n\nSpecifically, the actors may exploit these flaws through multiple vectors:\n\nAuthentication bypass;\n\nArbitrary code injection; and\n\nWeak configurations.\n\nUpon successful exploitation of the flaws, the actors could achieve the following effects:\n\nChange of temperature, which could:\n\nAffect the service life of the system;\n\nCreate a fire hazard;\n\nCause loss of inventory; or\n\nIndirectly harm consumers if products are consumed after unsafe storage.\n\nLoss of visibility into current temperatures (a denial-of-view condition).\n\nMitigations\n\nThe authoring organizations urge owners and operators to immediately take the following actions. These mitigations align with the\nCross-Sector Cybersecurity Performance Goals (CPGs)\n, developed by CISA and the National Institute of Standards and Technology (NIST). The CPGs provide a minimum set of practices and protections that CISA and NIST recommend all organizations implement:\n\nEliminate public internet exposure\n: Do not expose control system devices and/or systems, particularly controller panels, to the internet [\nCPG 3.S\n]. Should remote access be necessary, protect it by using a firewall or edge device and updating it to the latest version to reduce security vulnerabilities. See CISA’s\nInternet Exposure Reduction Guidance\nand\nDefend the Edge: The Critical Importance of Edge Device Security\nfor additional guidance on securing edge devices.\n\nIsolate operational technology (OT) devices\n: Create a dedicated OT virtual local area network (VLAN) to separate OT devices from business networks [\nCPG 3.I\n].\n\nEnforce credential security\n: Change default passwords [\nCPG 3.A\n], strengthen passwords, and implement strong password policies [\nCPG 3.B\n]. Further, implement phishing-resistant multifactor authentication wherever feasible [\nCPG 3.F\n].\n\nApply patches\n: Keep device firmware up to date and establish a structured lifecycle management process to identify, retire, and replace legacy devices that are at end of life (EOL) and no longer supported by the manufacturer [\nCPG 2.A\n,\n2.B\n]. See CISA’s\nBOD 26-04: Implementation Guidance for Prioritizing Security Updates Based on Risk\nand\nBOD 26-02: Mitigating Risk From End-of-Support Edge Devices\nfor additional guidance.\n\nRestrict access\n: Define and maintain device and IP address allowlisting, limiting access to only those devices and IP addresses authorized to make changes [\nCPG 3.H\n].\n\nHave reliable backups\n: Maintain current backups offsite and offline and test them [\nCPG 3.O\n].\n\nMonitor and report\n: Enable logging…","url":"https://cisa.gov/resources-tools/resources/us-government-partners-urge-hardening-industrial-refrigeration-and-cold-chain-monitoring-systems","published_at":"2026-11-05T12:00:00Z","updated_at":"2026-11-05T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028734Z","severity":"unknown","cvss_score":null,"epss":null,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":null,"vuln_ids":[],"tags":[],"cluster_id":null,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/53","html":"https://vulnwatch.ve1ve2.com/item/53"}},{"id":55,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"CISA Adds One Known Exploited Vulnerability to Catalog","summary":"CISA has added one new vulnerability to its\nKnown Exploited Vulnerabilities (KEV) Catalog\n, based on evidence of active exploitation.\n\nCVE-2024-27834\nApple Multiple Products Improper Authentication Vulnerability\n\nThis type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.\n\nBinding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk\nestablishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied.\n\nWhile BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of\nKEV Catalog vulnerabilities\n. CISA will continue to add vulnerabilities to the catalog that meet the\nspecified criteria\n.\n\nAware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s\nKEV Nomination Form\n. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.","url":"https://cisa.gov/news-events/alerts/2026/11/04/cisa-adds-one-known-exploited-vulnerability-catalog","published_at":"2026-11-04T12:00:00Z","updated_at":"2026-11-04T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028739Z","severity":"unknown","cvss_score":null,"epss":0.01558,"is_kev":true,"has_exploit":true,"kev_due_date":"2026-11-18","vendor":"apple","product":"Multiple Products","vuln_id":"CVE-2024-27834","vuln_ids":["CVE-2024-27834"],"tags":[],"cluster_id":51,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/55","html":"https://vulnwatch.ve1ve2.com/item/55"}}],"total":30,"has_more":false,"next_cursor":null,"limit":50,"page":1,"grouped":false,"filter":{"builds":"exclude","source":"cisa-advisories"}}