{"vuln_id":"CVE-2026-106175","aliases":[],"description":null,"published_at":null,"modified_at":null,"first_seen_at":"2026-11-21T19:15:04.075973Z","severity":"unknown","severity_source":null,"cvss_score":null,"cvss_vector":null,"cwe":[],"vendor":null,"product":null,"kev":{"is_kev":false,"date_added":null,"due_date":null,"ransomware":false},"epss":0.001,"epss_percentile":0.00824,"nvd_status":null,"enriched_at":null,"links":{"nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-106175"},"matched_alias":null,"items":[{"id":40,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens RUGGEDCOM APE1808","summary":"View CSAF\n\nSummary\n\nFortinet has published information on a Double Free vulnerability in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to update Fortigate NGFW to V7.6.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information\n\nThe following versions of Siemens RUGGEDCOM APE1808 are affected:\n\nRUGGEDCOM APE1808 vers:all/* (CVE-2026-106175)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 2.3\n\nSiemens\n\nRUGGEDCOM APE1808\n\n1 Vulnerability\n\nDouble Free\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-106175\n\nA Double Free vulnerability [CWE-415] in FortiOS, FortiProxy and FortiSwitch may allow a local authenticated attacker to crash the newcli daemon via crafted CLI commands.\n\nRead More\n\n1 Affected Product\n\nRUGGEDCOM APE1808 with Fortinet NGFW\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate Fortigate NGFW to V7.6.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-415 Double Free\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n2.3\n\nLOW\n\nCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported this vulnerability to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for\ncontrol systems security recommended practices\non the ICS webpage on\ncisa.gov/ics\n. Several CISA products detailing cyber defense best practices are available for reading and download, including\nImproving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies\n.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for\nproactive defense of ICS assets\n.\n\nAdditional mitigation guidance and recommended practices are publicly available on the ICS webpage at\ncisa.gov/ics\nin the technical information paper,\nICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies\n.\n\nOrganizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.\n\nAdvisory Conversion D…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-07","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028698Z","severity":"low","cvss_score":3.1,"epss":0.001,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":"fortinet","product":null,"vuln_id":"CVE-2026-106175","vuln_ids":["CVE-2026-106175"],"tags":[],"cluster_id":33,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/40","html":"https://vulnwatch.ve1ve2.com/item/40"}}]}