{"vuln_id":"CVE-2026-120271","aliases":[],"description":"InfoScan contains an unauthenticated information disclosure vulnerability in its mobile-enumeration and version-reporting endpoints. A remote attacker can send HTTP requests without authentication to retrieve system configuration information, including usernames and display names, multifactor authentication configuration status, session settings, application version information, server details, hardware module firmware versions, and the BACnet/IP port used by the installation.","published_at":"2026-11-19T18:18:03.920000Z","modified_at":"2026-11-19T21:17:46.183000Z","first_seen_at":"2026-11-21T19:15:04.069676Z","severity":"medium","severity_source":"nvd","cvss_score":6.9,"cvss_vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","cwe":["CWE-497"],"vendor":null,"product":null,"kev":{"is_kev":false,"date_added":null,"due_date":null,"ransomware":false},"epss":0.00401,"epss_percentile":0.3515,"nvd_status":"Received","enriched_at":null,"links":{"nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-120271"},"matched_alias":null,"items":[{"id":9026,"source":{"id":"nvd","name":"NVD CVE API 2.0"},"title":"CVE-2026-120271: InfoScan contains an unauthenticated information disclosure vulnerability in its mobile-enumeration and version-reporting endpoints. A remote attacker can send…","summary":"InfoScan contains an unauthenticated information disclosure vulnerability in its mobile-enumeration and version-reporting endpoints. A remote attacker can send HTTP requests without authentication to retrieve system configuration information, including usernames and display names, multifactor authentication configuration status, session settings, application version information, server details, hardware module firmware versions, and the BACnet/IP port used by the installation.\n\nReferences:\nhttps://www.cisa.gov/news-events/ics-advisories/icsa-26-321-01","url":"https://nvd.nist.gov/vuln/detail/CVE-2026-120271","published_at":"2026-11-19T18:18:03.920000Z","updated_at":"2026-11-19T21:17:46.183000Z","fetched_at":"2026-11-21T19:15:31.484681Z","severity":"medium","cvss_score":6.9,"epss":0.00401,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-120271","vuln_ids":["CVE-2026-120271"],"tags":["CWE-497"],"cluster_id":24,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/9026","html":"https://vulnwatch.ve1ve2.com/item/9026"}},{"id":32,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Dorsett Controls InfoScan","summary":"View CSAF\n\nSummary\n\nSuccessful exploitation of these vulnerabilities could allow an attacker to retrieve sensitive system information, access application data without authorization, recover stored credentials, or intercept and manipulate network communications.\n\nThe following versions of Dorsett Controls InfoScan are affected:\n\nInfoScan <=1.45.0 (CVE-2026-117659, CVE-2026-120157, CVE-2026-120255, CVE-2026-120260, CVE-2026-120271, CVE-2026-120298)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 8.1\n\nDorsett Controls\n\nInfoScan\n\n5 Vulnerabilities\n\nImproper Certificate Validation, Exposure of Sensitive System Information to an Unauthorized Control Sphere, Use of Hard-coded Cryptographic Key, Missing Authentication for Critical Function, Generation of Error Message Containing Sensitive Information\n\nBackground\n\nCritical Infrastructure Sectors:\nWater and Wastewater Systems\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nUnited States\n\nVulnerabilities\n\nExpand All +\n\nCVE-2026-117659\n\nThe InfoScan Electron desktop client improperly handles TLS certificate errors by accepting certificates without validating their trustworthiness. The client also configures Electron with nodeIntegration enabled, contextIsolation disabled, and webSecurity disabled. These settings weaken the client’s security boundaries. An attacker who is able to intercept or manipulate network communications may be able to present an untrusted certificate without the application rejecting the connection.\n\nRead More\n\n1 Affected Product\n\nDorsett Controls InfoScan <=1.45.0\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nDorsett Controls recommends updating affected versions of InfoScan to v1.46 or higher. To install the security patch, user administrators will need to log in to InfoScan and select System Maintenance from the menu. Once the System Maintenance application is open, select Check for Updates, and click the Install Now button in the Ready To Install section. If you are an offline customer (InfoScan has no internet access), you will need to download the update from the Dorsett Controls Customer Portal by selecting the InfoScan Update tile, downloading the update, and following the instructions listed on the portal.\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-295 Improper Certificate Validation\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n8.1\n\nHIGH\n\nCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N\n\n4.0\n\n8.5\n\nHIGH\n\nCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N\n\nView CVE Details\n\nCVE-2026-120157\n\nThe publicly distributed InfoScan Electron installer contains configuration files identifying hostnames associated with customer installations and internal development, testing, and database infrastructure. An individual who obtains and inspects the installer can extract these hostnames without authenticating to the affected systems.\n\nRead More\n\n2 Affected Products\n\nDorsett Controls InfoScan <=1.45.0\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nDorsett Controls recommends updating affected versions of InfoScan to v1.46 or higher. To install the security patch, user administrators will need to log in to InfoScan and select System Maintenance from the menu. Once the System Maintenance application is open, select Check for Updates, and click the Install Now button in the Ready To Install section. If you are an offline customer (InfoScan has no internet access), you will need to download the update from the Dorsett Controls Customer Portal by selecting the InfoScan Update tile, downloading the update, and following the instructions listed on the portal.\n\nDorsett Controls InfoScan <=1.45.0\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nDorsett Controls recommends updating affected versions of InfoScan to v1.46 or higher. To install the security patch, user administrators will need to log in to InfoScan and select System Maintenance from the menu. Once the System Maintenance application is open, select Check for Update…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-01","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028677Z","severity":"high","cvss_score":8.5,"epss":0.00401,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-117659","vuln_ids":["CVE-2026-117659","CVE-2026-120157","CVE-2026-120255","CVE-2026-120260","CVE-2026-120271","CVE-2026-120298"],"tags":[],"cluster_id":20,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/32","html":"https://vulnwatch.ve1ve2.com/item/32"}}]}