{"vuln_id":"CVE-2026-64629","aliases":[],"description":null,"published_at":null,"modified_at":null,"first_seen_at":"2026-11-21T19:15:04.069666Z","severity":"unknown","severity_source":null,"cvss_score":null,"cvss_vector":null,"cwe":[],"vendor":null,"product":null,"kev":{"is_kev":false,"date_added":null,"due_date":null,"ransomware":false},"epss":0.00168,"epss_percentile":0.06069,"nvd_status":null,"enriched_at":null,"links":{"nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-64629"},"matched_alias":null,"items":[{"id":31,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens Simcenter Femap","summary":"View CSAF\n\nSummary\n\nSimcenter Femap is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.\n\nThe following versions of Siemens Simcenter Femap are affected:\n\nSimcenter Femap vers:intdot/<2606.0002 (CVE-2026-64629)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 7.8\n\nSiemens\n\nSimcenter Femap\n\n1 Vulnerability\n\nOut-of-bounds Read\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nCVE-2026-64629\n\nThe affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.\n\nRead More\n\n1 Affected Product\n\nSimcenter Femap < V2606.0002\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V2606.0002 or later version\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-125 Out-of-bounds Read\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n7.8\n\nHIGH\n\nCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported this vulnerability to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for\ncontrol systems security recommended practices\non the ICS webpage on\ncisa.gov/ics\n. Several CISA products detailing cyber defense best practices are available for reading and download, including\nImproving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies\n.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for\nproactive defense of ICS assets\n.\n\nAdditional mitigation guidance and recommended practices are publicly available on the ICS webpage at\ncisa.gov/ics\nin the technical information paper,\nICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies\n.\n\nOrganizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.\n\nAdvisory Conversion Disclaimer\n\nThis ICSA is a verbatim republication of Siemens Produc…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-10","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028674Z","severity":"low","cvss_score":3.1,"epss":0.00168,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-64629","vuln_ids":["CVE-2026-64629"],"tags":[],"cluster_id":19,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/31","html":"https://vulnwatch.ve1ve2.com/item/31"}}]}