{"vuln_id":"CVE-2026-85114","aliases":["CVE-2026-85115"],"description":null,"published_at":null,"modified_at":null,"first_seen_at":"2026-11-21T19:15:04.072784Z","severity":"unknown","severity_source":null,"cvss_score":null,"cvss_vector":null,"cwe":[],"vendor":null,"product":null,"kev":{"is_kev":false,"date_added":null,"due_date":null,"ransomware":false},"epss":0.0033,"epss_percentile":0.26646,"nvd_status":null,"enriched_at":null,"links":{"nvd":"https://nvd.nist.gov/vuln/detail/CVE-2026-85114"},"matched_alias":null,"items":[{"id":34,"source":{"id":"cisa-advisories","name":"CISA Cybersecurity Advisories"},"title":"Siemens .NET Client Library for SIMATIC S7 Webserver API","summary":"View CSAF\n\nSummary\n\n.NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version.\n\nThe following versions of Siemens .NET Client Library for SIMATIC S7 Webserver API are affected:\n\n.NET Client Library for SIMATIC S7 Webserver API vers:intdot/<3.3.61, vers:intdot/<3.3.62 (CVE-2026-85114, CVE-2026-85115)\n\nCVSS\n\nVendor\n\nEquipment\n\nv3 7.5\n\nSiemens\n\n.NET Client Library for SIMATIC S7 Webserver API\n\n2 Vulnerabilities\n\nImproper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Generation of Error Message Containing Sensitive Information\n\nBackground\n\nCritical Infrastructure Sectors:\nCritical Manufacturing\n\nCountries/Areas Deployed:\nWorldwide\n\nCompany Headquarters Location:\nGermany\n\nVulnerabilities\n\nExpand All +\n\nCVE-2026-85114\n\nAffected applications do not properly validate filenames received from remote servers during ticket downloads. This could allow an attacker who can manipulate the ticket response to write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application.\n\nRead More\n\n1 Affected Product\n\n.NET Client Library for SIMATIC S7 Webserver API < V3.3.61\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V3.3.61 or later version\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n7.5\n\nHIGH\n\nCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\n\nView CVE Details\n\nCVE-2026-85115\n\nAffected applications do not properly redact PLC restore passwords from HTTP error exception messages. This could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC.\n\nRead More\n\n2 Affected Products\n\n.NET Client Library for SIMATIC S7 Webserver API < V3.3.61\n\nProduct Status: known_affected\n\nRemediations\n\n.NET Client Library for SIMATIC S7 Webserver API < V3.3.62\n\nProduct Status: known_affected\n\nRemediations\n\nVendor fix\nUpdate to V3.3.62 or later version\n\nAdditional Metrics\n\nRelevant CWE:\n\nCWE-209 Generation of Error Message Containing Sensitive Information\n\nCVSS Version\n\nBase Score\n\nBase Severity\n\nVector String\n\n3.1\n\n5.5\n\nMEDIUM\n\nCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\n\nView CVE Details\n\nAcknowledgments\n\nSiemens ProductCERT reported these vulnerabilities to CISA.\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.\n\nMinimize network exposure for all control system devices and/or systems, ensuring they are\nnot accessible from the internet\n.\n\nLocate control system networks and remote devices behind firewalls and isolating them f…","url":"https://cisa.gov/news-events/ics-advisories/icsa-26-321-02","published_at":"2026-11-17T12:00:00Z","updated_at":"2026-11-17T12:00:00Z","fetched_at":"2026-11-21T19:15:04.028684Z","severity":"low","cvss_score":3.1,"epss":0.0033,"is_kev":false,"has_exploit":false,"kev_due_date":null,"vendor":null,"product":null,"vuln_id":"CVE-2026-85114","vuln_ids":["CVE-2026-85114","CVE-2026-85115"],"tags":[],"cluster_id":28,"links":{"self":"https://vulnwatch.ve1ve2.com/api/v1/items/34","html":"https://vulnwatch.ve1ve2.com/item/34"}}]}